9900 Series reliability for medium size enterprise data centers, communications, manufacturing, and medical equipment.
The 9900AEGIS is the smallest in the popular 9900 series UPS from Mitsubishi Electric. Like all other Mitsubishi Electric UPSs, the AEGIS™ is a three-phase, on-line double-conversion system and features Mitsubishi Electric's world-renowned 3 Level Insulated Gate Bipolar Transistor (IGBT) technology for enhanced UPS performance and reliability. The AEGIS™ series is available in 80, 100, 150, 160, and 225 kVA and is UL924 listed (Standard for Emergency Lighting). One of the outstanding features of the AEGIS™ is that it boasts a relatively flat efficiency curve indicating that the UPS is highly efficient regardless of the load. This is significant since loads in various data centers can range anywhere from 25% to nearly 100%. The AEGIS™ can be configured both as a single module or in multi-module systems up to 4 units.
If downtime in your business equals disaster, Mitsubishi Electric delivers the highest reliability among backup power equipment suppliers through robust proprietary technology designed to deliver continuous power in the most demanding environments. Whereas competitors only estimate their reliability, Mitsubishi Electric’s installed base of 9900 series Uninterruptible Power Supplies have sustained load carrying capability more than 99.9992% of their actual operational history.
All the Power. Smaller Footprint.
The 9900AEGIS™ Series UPS creates more white space by minimizing the gray space it occupies. It can handle the same load in a significantly smaller footprint than competitive models, meaning more space can be allocated to revenue generation. The 9900AEGIS™ also has a higher power density than comparable UPSs, maximizing power output while minimizing gray space. These characteristics make it the UPS of choice in medical facilities across the country.
How an IGBT power device is controlled is key to achieving optimum performance characteristics of a UPS. Utilizing a combination of high sampling rates and Direct Digital Control (DDC), the 9900AEGIS™ is able to provide superior performance under all load conditions.
Benefits to the customer include excellent output voltage control, dynamic inverter response, and minimal voltage distortion during full load steps without the DC source. These characteristics maximize the performance of the UPS and increase the overall reliability of components and the system.
3 Level Double Conversion Technology
Advanced Circuit Topology and PWM
Low Input Harmonics, Internal Static Bypass
Board Level Self Diagnostics
Dual Input
Available for Parallel Redundant & Capacity Applications (Up to 4 Modules)
Output Power Factor 0.9
Optional enviro-mode operation: up to 99% efficiency
1.1:1 Generator Sizing
Lithium Ready™
As UPS systems are often viewed as one of the biggest culprits regarding energy loss in power distribution, it makes sense to consider efficiency, along with reliability, as a primary factor in the selection of a UPS.
Through its history of technological developments, Mitsubishi Electric has proven to be a leader in advancing efficiencies to unprecedented levels. Beginning with the use of IGBTs for converters and inverters and 3 level topology and followed by the promotion of transformerless designs, Mitsubishi Electric has long been at the forefront of offering Uninterruptible Power Supplies with the highest efficiencies available coupled with unparalleled reliability. Mitsubishi Electric's superior expertise in optimizing power device control is evident by the flatness of the resulting curve, demonstrating high efficiency across all load levels. Please note that all efficiency curves published on this site are for the respective UPS operating in true online double conversion (aka VFI).
While the UPS is the most critical piece of infrastructure in a data center, the DC power backup storage system that supports the UPS is not far behind.
We offer various DC power solutions, and provide information on both lithium ion and VRLA battery cabinets in the Peripherals section below.
For a deeper dive into all possible solutions, be sure to review our webpage entitled UPS Batteries and DC Power Storage Solutions or simply click here.
Designed with wrap around contactor for increased reliability and added redundancy
provide longer life and enhanced dependability
provide increased reliability and reduced maintenance costs
for easy repair and install